Back to shop
1 / 7

A customer's Fendt 724. The module in a weatherproof box bolted under the cab. Full wiring on the use-case page.

ISOBUS switch box replacement for the tractor cab

Each toggle becomes a button on the tractor screen or the joystick. ISOBUS Block switches the same valves and lights, and connects to the tractor's rear ISOBUS socket on one cable.

ISOBUS Block 8-Channel Relay Module

CA$1,530No Canadian sales tax added
In stock

Free shipping on all orders, via DHL Express.

Ships within 1 business day. DHL Express, usually 3–6 business days to Canada.

Any import taxes and duty are paid on delivery.

Connector kits

Optional. Each kit is the mating connector plus loose contacts you crimp to your own wiring.

ISOBUS cable. Choose one length, or none.
Coil of black HELUKABEL ISOBUS PUR cable with one end stripped: four thin red, yellow, black and green CAN cores, a red and black 2.5 mm² pair and a thick red and black 6 mm² pair

Supply, module power and CAN from the tractor's ISOBUS socket, in one cable. Add the External Connector Kit for the plug at the tractor end.

Photos and details
TotalCA$1,530
30-day money-backTry it on your machine. Full refund if it's not right.
Ships from FinlandFree to Canada
5-year warrantyCovers the module
Field-tested onJohn Deere · Fendt · Claas · Case IH · New Holland · Massey Ferguson · Valtra

Returned complete and undamaged. Buyer pays return postage. Custom kits excluded; faults covered by the 5-year warranty.

Warranty TermsReturnsTerms of Sale

Payments by Stripe · Visa, Mastercard, Apple Pay, Klarna

Not sure it fits? Check in 30 s

A panel on the dash, a cable through the window

Installers see the same cab again and again: cheap switches for pumps and electric valves, a panel on the dash or the pillar, and several cables through the rear window. Each toggle powers one valve or one light on the implement. The toggles wear, the grommet in the window cracks, and the panel only fits the implement it was wired for.

With ISOBUS Block on the implement, each toggle gets a button on the tractor screen, named for what it switches. Joystick or armrest buttons take the functions you switch most, so you no longer reach for the dash. The module connects to the tractor's rear ISOBUS socket, and nothing passes through the window.

The layout changes on the screen as well. Rename a button, give it another icon or change the outputs it switches, without touching a wire.

From toggle panel to tractor screen

  1. Mount the module in an enclosure on the implement frame.
  2. Connect the toggle wires to the relay outputs, one load per output.
  3. Remove the old cable from the window and connect the module to the rear ISOBUS socket with the External Connector Kit.
  4. Give each button the name its toggle had, then assign the busiest ones to joystick buttons.

What you need

  • ISOBUS Block 8-channel module.
  • External Connector Kit. The plug for the rear ISOBUS socket, with the module mounted on the implement.
  • ISOBUS cable in 3 m (10 ft), 6 m (20 ft) or 10 m (33 ft).

On customers' machines

  • A customer's machine: an Amazone Pantera being converted from a sprayer into a harvesting machine. A 32-channel build switches its new functions.

  • A hook-lift trailer in the UK, fitted by our dealer Tramline Tec. The 32-channel module in an enclosure on the chassis. We ship the module only; the box, terminals and wiring are the installer's.

  • A customer's Fendt 724. The module in a weatherproof box bolted under the cab. Full wiring on the use-case page.

  • A customer's potato trailer in the UK. The 8-channel module in an enclosure on the trailer replaced the switch box in the cab.

What customers tell us

  • It was a pleasure to work with you, very knowledgeable and nothing too much of a problem. Great piece of ingenuity.
    Robert N.United Kingdom. Potato windrower and trailers, 32-channel and 8-channel modules.
  • A customer in Austria fitted the module to a new Fendt 724 and wired six channels to the 15-pin socket for a three-way tipper, with two spare in the cab. He wrote that the install was plug and play and that controlling the tipper from the terminal is comfortable.

    Austria. Fendt 724 Gen6, three-way tipper with lift axle.

  • Excellent customer service. The rake worked really well all season, much easier steering with the ISOBUS Block installed.
    A. S.Norway. Krone Swadro 800 twin-rotor rake.

Name it. Assign it. Press it.

Mount it, wire your loads, plug in one ISOBUS cable, and set up your buttons on the tractor screen. A screwdriver does the module end.

ISOBUS Block button editor: set name, icon, outputs, and mode
Step 1

Name your button

Type a name (up to 8 characters), pick an icon, select which outputs it controls, and choose toggle or momentary mode.

ISOBUS Block dashboard with custom-named buttons and icons
Step 2

See it on the screen

Your buttons show up on the tractor display with the names and icons you chose. Pick a layout that fits your setup.

Tractor armrest with all ISOBUS Block buttons assigned
Step 3

Assign to your joystick

Open the tractor's AUX-N menu. Your named buttons appear there. Assign them to any joystick or armrest button you want.

ISOBUS Block dashboard with active relay outputs highlighted green
Step 4

Press it

Your joystick button switches the relay. Active outputs light up green on the screen. That's the whole system.

What actually changes

Same tractor. Same cab. Completely different setup.

Drilling holes, mounting switches
Clean cab, no modifications
Relay boards, fuses, wiring looms
One ISOBUS cable, done
Hard-wired, can't change it
Reassign any output from the screen
Reaching across the cab for switches
Everything on your joystick hand
Which switch was the work light again?
Labels on the tractor display

Description

A relay module that speaks ISOBUS. Wire the machine's valves, lights and motors to its 8 outputs and run them from the tractor's own screen and joystick. A full implement conversion, a third function on a front loader or a one-off build: same module, different wiring. Plug it into any ISOBUS tractor and it appears on the screen. Name the buttons, pick the icons and put the ones you use most on the joystick or armrest. No second screen, no laptop, no software. 8 × 10 A relay outputs with NO, COM and NC terminals, and 8 digital inputs for sensors and switches. DIN-rail housing, IP20: in the cab, or in a weatherproof enclosure on the implement. In the box: the module and a quick-start guide.

AUX-N Control

ISOBUS Block Virtual Terminal interface on Fendt screen with custom channel names and icons

The module's buttons on a Fendt terminal

Fendt AUX-N assignment page showing ISOBUS Block custom names and icons on joystick buttons

The same buttons on the Fendt AUX-N assignment page

See it in action

The actual screens you'll use: button editor, layout options, AUX-N assignment, and more.

ISOBUS Block layout selector: 2x4, 4x2, 1x8, BIG4, BIG2
AUX-N assignable functions list with custom ISOBUS Block names and icons
ISOBUS Block edit mode: all buttons highlighted blue, tap to edit

Control outputs from the screen too. Five button layouts to choose from

Let a sensor do the switching

The module has 8 digital inputs. Wire a proximity sensor, a limit switch, a pressure switch or a cab panel switch to one, and it switches the relay outputs for you. 5 to 36 V, optocoupler isolated, for dry contact, NPN and PNP sensors.

You decide when it runs: arm it from the tractor screen or from an armrest button. Everything is set up on the terminal. No laptop, no app, no programming.

A customer arms an AUTO tile on the terminal, then the sensor that runs it, out on the implement.
How the inputs work
Follow

Output on while the input is active.

A sensor on the wagon door. When the load pushes the door open, a buzzer sounds in the cab.

Toggle

Each pulse flips the output on or off.

Block

Forces the outputs off while the input is active.

For an end switch or a limit switch. It stops the automation, never your own button press.

Manual always wins

Grab the joystick and the automation drops out. Any joystick, armrest or screen button that overlaps a running function disarms it. The automation never blocks, limits or delays what you do by hand.

  • Automation never resumes by itself. Re-arming is one deliberate press.
  • Nothing arms itself. After a power cycle everything is manual again.
  • A latched STOP holds every output off until you release it. It is an operator control, not an emergency stop.

Tune each input to the machine

Five settings per input, stored per preset. A live IN and OUT indicator on the same terminal page shows the raw sensor next to the filtered result.

SettingWhat it doesRange
DebounceFilters contact bounce and electrical noise.10 ms to 1 s
On delayThe sensor has to mean it before anything moves. Ignores bumps and blips.0 to 10 s
Off delayStops hunting when a sensor sits right on its trigger point.0 to 10 s
Min onOnce on, the relay stays on at least this long, so a twitchy sensor cannot chatter it and wear it out.0 to 10 s
Max onCeiling on continuous on-time. Catches a sensor that fails stuck-on.No limit, or 1 to 300 s

Hard floors of 100 ms on and 100 ms rest are built in. No combination of settings can chatter a relay from the input side.

What it is not

This is not a safety system. Block inputs and interlocks stop the automation, not you. If a movement has to stop whatever happens, fit a mechanical end stop.

An input is on or off. It does not measure a level, count pulses or read a frequency. Two inputs can be interlocked so they never run at the same time. That is the only logic between them.

The web interface only tests outputs and updates firmware. Switching an output there turns all automation off.

Read the automation guide

Built for the field

8 relay channels, 10A each, 7–36V input. Set up everything from the tractor screen.

Supply voltage7–36V DC
Relay channels8 (NO, COM, NC per channel)
Max current10A per channel
Max switching voltage30V DC / 250V AC
ProtectionOptocoupler isolation, power isolation
EnclosureRail-mount ABS housing (indoor use; requires weatherproof enclosure for outdoor installation)
Dimensions90 × 175 mm
Weight500 g
Operating temperature−30°C to +50°C
Warranty5 years

Optional add-ons

Connector kits and cable

Where you mount the Block decides the connector. In the cab, it plugs into the tractor's in-cab ISOBUS socket. On the implement, it plugs into the external socket at the rear or front, and the ISOBUS cable runs from there to the Block.

None of these are required. The module takes any ISOBUS cable you source yourself. The kits and the cable just save you sourcing the parts.

Add them next to Add to cart at the top of this page.

Questions?

More from the ISOBUS Block platform